Kerlink Wirnet iStation
System Requirements
- OS - 4.3.3
Common Packet Forwarder
The common packet forwarder must be enabled and running before installation of the SenRa Packet Forwarder. Please refer to the Kerlink CPF documentation for enabling the Common Packet Forwarder on your platform.
Example Configuration:
Go to the lorad folder for your platform:
cd /etc/lorad/wiis/
Copy the channel plan for your region to a new name:
cp IN865-IN.json IN865-IN_SenRa.json
Edit lorad config in order to start lorad:
vi /etc/default/lorad
Set DISABLE_LORAD to no
DISABLE_LORAD="no"
Set CONFIGURATION_FILE to the full path of the channel plan file you just created for your platform
CONFIGURATION_FILE="/etc/lorad/wiis/IN865-IN_SenRa.json"
Exit and save the file
Reboot the system to restart all the processes:
reboot
SenRa Packet Forwarder
Registration
If you have not done so already you will need to register your gateway through your Developer or RAN Provider account.
Note
The serial number for this device is "0x" followed by the last 4 Bytes of the EUI which can be found on bottom of the Gateway. Alternatively it can be found by looking at the serial_number object in this file: /tmp/sys_startup_status.json
Installation
Copy and paste the following command into the Kerlink Wirnet iStation SSH console.
OS Version | Command | |
---|---|---|
OS 4.3.3 |
|
Run the command. The installation is automatic and will prompt you once it has completed.
reboot
Once registration and Gateway software installation are complete the Gateway will be displayed in the SenRa Portal Dashboard with the current registration status (this may require a refresh of the browser).