Tektelic KONA 16 Macro
Prerequisite
Verify Tektelic's default packet forwarder is not running
ps -eadf |grep -i pkt
If Tektelic's default packet forwarder is found to be running you will see a pkt_forwarder process running as shown in the example below.
If you do not see any processes running skip to the installation steps below.
#ps -eadf |grep -i pkt
root 2429 1 0 17:14 ? 00:00:37 /usr/bin/pkt_forwarder -c /etc/default/config.json -s
root 23729 23692 0 18:19 pts/0 00:00:00 grep -i pkt
Confirm the running forwarder is Tektelic's packet forwarder
opkg list-installed |grep pkt
If the installed forwarder running is Tektelic you will see kona-pkt-forwarder listed in the output.
#opkg list-installed |grep pkt
kona-pkt-forwarder - 4.0.17-r110
kona-pkt-forwarder-config - 4.0.17-r110
kona-pkt-forwarder-dvt-utils - 4.0.17-r110
kona-pkt-forwarder-utils - 4.0.17-r110
Remove the Tektelic packet forwarder
If the installed packet forwarder was confirmed to be Tektelic, remove the forwarder with the following command.
opkg remove kona-pkt-forwarder
Example output.
Removing package kona-pkt-forwarder from root...
Stopping Tektelic Packet Forwarder: Reinitializing monit daemon
Removing any system startup links for pkt_fwd ...
/etc/rc0.d/K10pkt_fwd
/etc/rc1.d/K10pkt_fwd
/etc/rc2.d/K10pkt_fwd
/etc/rc3.d/K10pkt_fwd
/etc/rc4.d/K10pkt_fwd
/etc/rc5.d/S99pkt_fwd
/etc/rc6.d/K10pkt_fwd
Verify the default packet forwarder is no longer running
ps -eadf |grep -i pkt
There should no longer be any running packet forwarder processes found.
root 11002 23692 0 19:20 pts/0 00:00:00 grep -i pkt
SenRa Packet Forwarder for Developers
Registration
If you have not done so already you will need to register your gateway through your Developer or RAN Provider account.
Note
The serial number for this device is the 8 digit Product Type (starting with a "T") an underscore "_" followed by the 9 digit serial number which can be found on bottom of the Gateway.
Installation
Copy and paste the following command into the Tektelic KONA 16 Macro SSH console.
BSP Version | Command | |
---|---|---|
BSP: 4.0.X |
|
Run the command. The installation is automatic and will prompt you once it has completed.
reboot
Once registration and Gateway software installation are complete the Gateway will be displayed in the SenRa Portal Dashboard with the current registration status (this may require a refresh of the browser).
SenRa Packet Forwarder for RAN Providers
Note
Before installing verify you have properly configured your network settings on the gateway. The installation process will apply security measures which include modifications to the firewall as well as the password; the installer may also configure the system and install new packages. Access to the gateway over the local network through such protocols as SSH and telnet will no longer be available upon completion of the installer.
Registration
If you have not done so already you will need to register your gateway through your Developer or RAN Provider account.
Note
The serial number for this device is the 8 digit Product Type (starting with a "T") an underscore "_" followed by the 9 digit serial number which can be found on bottom of the Gateway.
Installation
Copy and paste the following command into the Tektelic KONA 16 Macro SSH console.
BSP Version | Command | |
---|---|---|
BSP: 4.0.X |
|
Run the command. The installation is automatic and will prompt you once it has completed.
reboot
Once registration and Gateway software installation are complete the Gateway will be displayed in the SenRa Portal Dashboard with the current registration status (this may require a refresh of the browser).